OptiFiber Rental Service | Fiber Inspector For Rent | OTDR Rental Service | OptiFiber for Rent https://www.tech4rents.com/product-category/fiber-certification/ tech4rents Mon, 18 Jan 2021 12:43:39 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 DSX-5000QI https://www.tech4rents.com/product/dsx-5000qi/ https://www.tech4rents.com/product/dsx-5000qi/#respond Mon, 25 Sep 2017 10:32:09 +0000 http://tech4rents.com/?post_type=product&p=1504 1 Ghz DSX W/Quad OLTS Insp

The post DSX-5000QI appeared first on tech4rents.

]]>
DSX CableAnalyzer™ Series

Accelerates every step of the copper certification process

  1. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  2. Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  3. ProjX™ system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
  4. Taptive™ user interface simplifies set-up, and eliminates errors
  5. Analyze test results and create professional test reports using LinkWare™ management software
  6. Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting
  7. Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  8. Endorsed by cabling vendors worldwide
  9. Built in Alien Crosstalk testing capability
  10. Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

The DSX CableAnalyzer Series copper test solution enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Comparing the DSX-8000 and DSX-5000

The DSX CableAnalyzer Series family is based on two modules: the DSX-5000 and DSX-8000. The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.

Copper Certification
DSX-8000 CableAnalyzer™ DSX-5000 CableAnalyzer™
Category 6A / Class EA test time 8 seconds 10 seconds
Category 8 / Class I/II test time 15 seconds
HDTDX/HDTDR diagnostic test times ≈ 3 seconds ≈ 3 seconds
Internal memory ≈ 5,000 Cat 8 with plots≈ 12,000 Cat 6A with plots ≈ 12,000 Cat 6A with plots
Level V Accuracy (1 GHz)
Level VI/2G Accuracy (2 GHz)
Resistance Unbalance measurement
Shield integrity check
TCL measurement
ELTCTL measurement
CDNEXT measurement
CMRL measurement
Built in Alien XTalk module
Channel Adapter 2 GHz Range 1 GHz Range
Permanent Link Adapter 2 GHz Range 1 GHz Range
Optional Accessories
Patch cord adapters Category 5e, 6 and 6A patch cord Category 5e, 6 and 6A patch cord
Coax Adapter
M12 Adapter
TERA Adapter Coming Summer 2017
GG45 Adapter Coming Summer 2017

Unique Features:

  1. Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  2. LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  3. ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  4. Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  5. LinkWare PC management software provides unmatched analysis of test results and professional test reports
  6. The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Standards:

  1. Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
  2. Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) –IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
  3. TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
  4. Screen continuity along path of cabling

Performance:

  1. Eight second Cat 6A test time contributes to the fastest way to gain certification
  2. Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  3. Manage up to 12,000 Cat 6A test results with full graphics
  4. Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  5. Over 1 billion links reported on LinkWare PC management software

ProjX™ Management System Manages Complex Jobs with Ease

Manage up to 12,000 Cat 6A test results with full graphics

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX CableAnalyzer Series provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The “Fix Later” selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.

Project Setup screenProject menu screen shows percent complete per job. Arrow Project Menu Screen Specific screen shows up to the minute project details. Arrow Project Test Setup ScreenSet-up or view test limits, and testing attributes.

Performs with Unsurpassed Speed

Eight second Cat 6A test time and the fastest way to submit your certification results

No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 8 seconds or certify two fibers at two wavelengths in just 3 seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

Passing Test Results

LinkWare™ Live Test Results Management Service
LinkWare™ PC Cable Test Management Software
Versiv Platform is Ready for Today’s and Tomorrow’s Jobs

Troubleshoot Like an Expert – Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting

The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are located on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer Series removes this limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.

HTDTX shows the far end connection is clearly the issue Feature Simple Diagnostics
High Definition Time Domain Crosstalk (HTDTX) shows the far end connection in clearly the issue Features simple diagnostics based decades of Fluke Networks troubleshooting experience

Shield continuity historically is a direct current (DC) measurement with no distance to fault available. Other testers run a simple resistance test to verify that the shield has continuity. These tests have been shown to be inaccurate, sometime confusing a ground path as shield continuity and not correctly identifying a break in the shield. Other testers may tell you there is a break in a shield, but not pinpoint the exact location giving no indication of where to start rework. The DSX CableAnalyzer Series is the first field tester to report distance to any shield integrity issues, reporting the true status of the screen continuity. This is especially important in\ datacenters and Cat 8 installations where screen continuity is critical to maintaining alien crosstalk performance of screened cabling.

Wiremap Shows Distance to fault, break and short

Specifications

Cable Types
Shielded and unshielded pair LAN cabling TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω
ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω

 

Standard Link Interface Adapters
Permanent link adapters Plug type: shielded RJ45
Optional Plug type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)

 

Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2
ISO/IEC Class C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequency DSX-8000: 2000 MHz;
DSX-5000: 1000 MHz

 

General Specifications
Speed of Autotest DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA8 seconds. Full 2-way Autotest of Category 8: 16 seconds
DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with shock absorbing overmold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote: Lithium ion battery pack, 7.2 V
Typical battery life: 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year

 

Environmental Specifications
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -14°F to +140°F (-10°C to +60°C)
Operating relative humidity 0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude 13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMC EN 61326-1

 

Performance Specifications **
DSX-8000 Category 8 test modes (or lower link categories) ANSI/TIA-1152 Level 2G
Class I/II test modes Proposed standard IEC 61935-1 Ed. 5 Level VI
DSX-5000 Category 6A/Class EA test modes (or lower link categories) Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes Exceed Level V requirements as in the draft 4th edition of IEC 61935-1.

 

Length of Twisted Pair Cabling1
Without Remote With Remote
Range 800 m (2600 ft) 150 m (490 ft)
Resolution 0.1 m or 1 ft 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)

 

Propagation Delay
Without Remote With Remote
Range 4000 ns 750 ns
Resolution 1 ns 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)

 

Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns

 

DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.

 

Kit Components:

1 Versiv Mainframe & Remote, (2) DSX-5000 CableAnalyzer Modules, (2) CertiFiber Quad OLTS Modules, Set of Cat 6A/Class EA Permanent Link Adapters, Set of Cat 6A/Class EA Channel Adapters, (2) Headsets, (2) Handstraps, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, (2) Universal Couplers, USB Video Inspection Probe w/ 4 Tips, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) LC/LC Simplex Adapters, SC/LC EF-Compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carry Case, Statement of Calibration and Getting Started Guides.

The post DSX-5000QI appeared first on tech4rents.

]]>
https://www.tech4rents.com/product/dsx-5000qi/feed/ 0
MFTK-MM850-SM1310 https://www.tech4rents.com/product/mftk-mm850-sm1310/ https://www.tech4rents.com/product/mftk-mm850-sm1310/#respond Mon, 25 Sep 2017 10:30:13 +0000 http://tech4rents.com/?post_type=product&p=1502 Multifiber Pro Kit With 850/1310 NM PMLS

The post MFTK-MM850-SM1310 appeared first on tech4rents.

]]>
MultiFiber™ Pro Optical Power Meter and Fiber Test Kits

Introducing the MultiFiber™ Pro Optical Power Meter and Fiber Test Kits. 
MultiFiber Pro Optical Power Meter and Source is the only fiber tester that can certify MPO fiber trunks without the use of fan-out  cords. This singlemode and multimode MPO fiber testing kit eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field. Whether it is using 10 Gbps preterminated MPO fiber trunks or planning for next-generation 40/100 Gbps Ethernet performance, data centers are standardizing on an MPO connector solution. Typical data center fiber installation means time-consuming, manual and imprecise MPO validation. MultiFiber Pro Optical Power Meter and Source is 90 percent faster than single fiber cable certification because it measures power loss and validates polarity on 12 fibers in a single connector— reducing test time from weeks to days.

MultiFiber Pro Optical Power Meter

First MPO fiber tester to support both Singlemode and Multimode MPO fiber certification

  1. Automatic scanning and testing of all fibers in MPO connectors with “Scan All”
  2. Support for both Multimode and Singlemode MPO fiber trunks
  3. Eliminates the need for fan-out cords when testing MPO fiber trunks
  4. Easy to interpret test results with minimal navigation
  5. The user interface displays all 12 fibers
  6. Automatic 8, 10 and 12 fiber measurements
  7. Troubleshoot MPO fiber links and drill down to single fiber test results

Features

“Scan All” Function

The Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors – taking just 6 seconds to complete all loss or power measurements. This feature automates the certification of MPO terminated fibers and eliminates the time consuming and manual process of moving the fiber tester from fiber to fiber while using fan-out cords.

 

Built-in Polarity Verification

The simple purpose of any polarity scheme is to provide a continuous connection from the link’s transmitter to the link’s receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this: Methods A, B and C. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links and channels for correct polarity.

Polarity Measurement of MultiFiber Pro

 

On-board MPO Connector

Equipped with MPO connector on both the Optical Power Meter and Light Source, it eliminates the use of costly and complicated fan-out cords to test MPO fibers.

 MPO connector on MultiFiber Pro eliminates the use fan-out cords

Uncovered ports can put cabling, equipment and testers at risk for contamination and affect performance. Ensuring a covered connection on your tester can protect it from dirt and dust. MultiFiber Pro makes it easy by shuttering the MPO connector giving you greater test reliability and peace of mind.

Simple User Interface

The MultiFiber Pro is so successful at simplifying the task of simultaneously representing polarity, power and loss results for 12 fibers that the user interface is patent pending. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector that is being tested. Any individual measurement that fails the test limit is plainly identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert and increases efficiency in testing data center projects.

 
Select an Individual Fiber

One of the main problems in the data center is the ability to drill down to a single fiber during testing and troubleshooting. MultiFiber Pro can troubleshoot a single fiber within an MPO trunk and provide a single fiber test result. This ability increases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.

Easy Reporting

The MultiFiber Pro Power Meter stores up to 3,000 test results (or the equivalent of 250 MPO cables) internally which can be uploaded to a PC using the LinkWare™ 7 Cable Test Management Software. LinkWare 7 allows you to manage test results, edit cable ID’s, print professional reports and even export the data into spreadsheet formats.

LinkWare PC Cable Test Management Software Reports

Kits for Every Need

MultiFiber Pro is available in several convenient kit configurations to meet all your cleaning, inspection and verification testing needs. Some kits include:

FI-7000 FiberInspector Pro with MPO tip and cleaning supplies
The FI-7000 is the ultimate inspection tool. It enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It’s 2-second automated PASS/FAIL eliminates human subjectivity and enables anyone to become a fiber inspection expert.

  1. Automated Pass/Fail acceptance testing of fiber end-faces
  2. Large touchscreen for pinch and zoom
  3. Graphical indication of problem areas due to contamination, pits, chips, and scratches
  4. Certify to industry standards – IEC 61300-3-35
  5. Eliminate human subjectivity from end-face measurements
  6. Includes MPO tip for inspection probe and MPO cleaner

FI-7000 FiberInspector Pro with MPO tip

Fiber Cleaning – Quick Clean™ Cleaners
Cleaning is critical. Fluke Networks’ Quick Clean Cleaners instantly clean fiber optic bulkhead connectors and end-faces. Just push the tool tip to engage cleaning action and pull back on the wheel – it’s that simple. The MPO Quick Clean Cleaner is bundled with the MultiFiber Pro kits to ensure that you have the best cleaning tool from the beginning.

Fiber Cleaning - Quick Clean Cleaners

Specifications

Environmental        
Operating temperature -10ºC to +50ºC
Storage temperature -20ºC to +50ºC
Operating humidity 95% (10ºC to +35ºC) non-condensing
75% (35ºC to +45ºC) non-condensing
Uncontrolled <10ºC
Operating altitude 4,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz

 

Optical Power Meter (Specifications apply at 23ºC (73ºF), unless otherwise noted.)
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement range 0 dBm to -50 dBm
Test time 6 seconds
Power measurement linearity ±0.1 dB2
Power measurement uncertainty ±0.35 dB2
Power measurement repeatability < 0.10 dB2
Display resolution, dB or dBm 0.01
Power display units dBm, mW, µW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
2 kHz detection Yes
Record storage 3000 records, one fiber per record (250 12-fiber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm, 50 µm, and singlemode fibers. Connector has a self-closing, protective cover.
Power requirement 2 AA alkaline batteries
Battery life3 30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 10.9 oz (309 g)
  1. For 850 nm, 0 dBm to -50 dBm. For 1300, 1310, 1550 nm, -5 dBm to -50 dBm
  2. For a continuous-wave optical signal.
  3. Measured power levels≤ 0 dBm. Backlight on. Battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
  4. 23°C, after 10 minutes of warm-up time.
  5. 23°C, after 15 minutes of warm-up time.
  6. Auto wavelength, SCAN ALL, and backlight on. Battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.

 

 

Sources

  850 nm Source 1310 nm Source 1550 nm Source
Emitter type LED Laser
Wavelength ±30 nm 1310 nm ±20 nm 1550 nm ±20 nm
Spectral width (FWHM) 50 nm (typical) 2 nm typical, 5 nm maximum
Minimum output power ≥ -24 dBm ≥ -1 dBm
Power output stability ≤±0.1 dB over 8 hours4 ±0.25 dB over 8 hours5
Laser safety IEC 60825-1:Class 1
Encircled flux Meets TIA 455-526-14B, ISO/IEC 14763-3, and IEC 61280-4-1 for 50/125 µm at the source’s optical connector. NA
Optical connector MTP/MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm and 50 µm fibers, non-APC only. Connector has a self-closing, protective cover. MTP/MPO interface for 12-fiber, unpinned plugs. Compatible with 9 µm fibers, APC only. Connector has a self-closing, protective cover.
4. 23°C, after 10 minutes of warm-up time.

5. 23°C, after 15 minutes of warm-up time

Modes 2 kHz modulated, auto wavelength/td>
Power requirement 2 AA alkaline batteries
Battery life6 >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 11.4 oz (323 g)

 

Includes:

MultiFiber Pro Multimode & 1310 nm Singlemode Kit includes MultiFiber Pro Power Meter, 850 nm Light Source, 1310 nm Light Source, Test Reference Cords, MPO adapters, and carrying case. 

The post MFTK-MM850-SM1310 appeared first on tech4rents.

]]>
https://www.tech4rents.com/product/mftk-mm850-sm1310/feed/ 0
FI-7000-MPO https://www.tech4rents.com/product/fi-7000-mpo/ https://www.tech4rents.com/product/fi-7000-mpo/#respond Mon, 25 Sep 2017 10:24:42 +0000 http://tech4rents.com/?post_type=product&p=1500 Fiberinspector Pro W/MPO And Cleaning

The post FI-7000-MPO appeared first on tech4rents.

]]>
Fiber optic connector end-face contamination is a leading cause of fiber failures. Dirt and contaminant cause insertion loss and back-reflection that inhibits optical transmission and causes havoc with transceivers. Fiber loss and OTDR testing can expose this problem, but in many cases, dirty connections make fiber testing time consuming and inaccurate.

Since dirt can be an issue before, during, or after fiber optic certification testing, and migrate from one fiber optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected. Further, mating contaminated fiber optic connectors can cause permanent damage as microscopic debris is crushed between end-faces in physical contact. Even factory terminated patch cords or pigtails must be inspected as protective caps do not keep fiber optic connector end-faces clean. Avoiding this common cause of failure, starts with inspecting the fiber optic connector end-face and eliminating any contamination before insertion into a bulkhead or piece of equipment.

The FI-7000 FiberInspector Pro is a fiber optic inspection scope that allows you to inspect and certify fiber optic connector end-faces in 1 seconds so you can get the job done the first time. This fiber optic inspection scope provides automated PASS/FAIL certification take the guess work out of fiber inspection so anyone can be a fiber expert.

1-second automated PASS/FAIL certification of fiber optic connector end-faces
  1. Automated Pass/Fail certification of fiber optic connector end-faces
  2. Graphical indication of problem areas due to contamination, pits, chips, and scratches
  3. Certify to industry standards – IEC 61300-3-35
  4. Eliminate human subjectivity from fiber optic connector end-face measurements
  5. Save fiber optic connector end-face views during certification process
  6. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection

Features

Fiber Inspection Certification

Certify your fiber end-faces to industry standards – IEC 61300-3-35. Or if you prefer, you can manually grade your end-faces.
Graphical indication of Problem Areas
FiberInspector Pro highlights defects found on fiber end-faces. Instead of just coloring the defect area, the FI-7000 colors the defect and highlights the defect’s background so that the defect is clearly visible. Defects that fail the standard’s requirements are colored Red, while defects that pass are colored Green.
Store End-face Images
Store both end-face images of a fiber directly in your Versiv test results. Combine end-face images with CertiFiber Pro OLTS and/or OptiFiber Pro OTDR test results for the complete history of your fiber cabling health.
Built on the Versiv Platform
The FI-7000 is built on the Versiv Cable Certification Platform which enables you to easily add optical loss (OLTS) and Optical Time Domain Reflectometry (OTDR) or even twisted pair copper or network analysis functionality to FI-7000. Product add-on kits are available for the DTX CableAnalyzer, CertiFiber Pro OLTS, and OptiFiber Pro OTDR.
Versiv’s ProjX™ System

Versiv’s ProjX™ System manages jobs from setup to systems acceptance, ensuring that all tests are completed correctly. Enter the testing details for a job once, and ProjX stores them in a project file with a name the whole team can understand. Change modules or jobs without having to re-enter details. Support multiple testers on the same job by sharing project files via USB sticks or email. Easy just met efficient.

Set-up or view test limits, and testing attributes. Project menu screen shows percent complete
per job.
Project Specific screen shows up to the minute project details.

Taptive™ User Interface

Now you can test across multiple media types and requirements as easy as using a smartphone. Simply, select the job you’re working on, and the large display confirms the test that needs to be performed. Taptive helps you tap into the overall cabling infrastructure faster and more easily.

User Interface for Speeds Troubleshooting

Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting

LinkWare™ Live Test Results Management Service

LinkWare Live is a cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device.  With LinkWare Live, you can

  1. Keep track of every test on every job.  Get an overview of every project from any smart device. Drill down to each individual test. Instantly receive notification of incorrect test setting or cable IDs.
  2. Get it right the first time. Define cable IDs and test settings from your PC or tablet. Then send them to the testers or Brother printers at the jobsite for mistake-free testing and labeling.
  3. Keep your testers up to date. Standards can change without notice, and an out-of-date test report can mean hours of re-testing. LinkWare Live automatically ensures your testers are running the latest.
  4. Stop wasting time and gas driving testers back to the office. Upload your test results straight from the job site to LinkWare Live over Wi-Fi. Then download them automatically to the right job for fast report generation with LinkWare PC.
  5. Avoid Project Delays. Track the last used location and monitor the status of all testers to ensure they are always calibrated and running the latest firmware*
  6. Supports all Versiv models: DSX CableAnalyzer Series, CertiFiber Pro, OptiFiber Pro, and the FI-7000.

LinkWare™ Management Software

Project managers have full capabilities to monitor workflow and consolidate test results.

LinkWare pulls data togther into a single report that is easy for customers to understand, showcasing quality and workmanship. LinkWare stats, provides automated statistical reports that turns test results into charts to reveal performance. The report even summarizes your entire cabling and fiber infrastructure in one compact, graphical format, so it is easy to verify margins and anomalies.

LinkWare Management Software  LinkWare Stats Summary
Integrate tests from different testers into one unified report. LinkWare Stats summarizes all project data

PASS/FAIL Fiber End-face Grading

The FI-7000’s PASS/FAIL fiber end-face grading is available to all Versiv owners. It is included in Versiv firmware v3.0 and higher. To enjoy this free fiber end-face grading, just download the latest Versiv firmware and create a new Project using FiberInspector as the test.

Specifications

Technical Specifications

Inspection Probe specifications
2M pixels Blue LED
Light source Blue LED
Power source Versiv mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (-20°C to +70°C)
Certifications CE
General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eleven hour with Inspection probe attached
Charge Time
Tester Off Four hours to charge from 10% to 90% capacity
Tester On Six hours to charge from 10% to 90% capacity with the tester on
Environmental specifications
Operating temperature* -18ºC to 45ºC
Non-operating temperature -30ºC to 60ºC
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with ac adapter
Storage altitude 12,000 m
EMC EN 61326-1
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.
Kit Components:
The FI-7000 FiberInspector Pro with MPO tip and cleaning contains: Versiv Mainframe, USB Fiber Inspection Video Probe with 4 tips in a box (LC, FC/SC bulkhead, 1.25 and 2.5mm universal), MPO Fiber Inspection Adapter Tip, Quick Clean Cleaners for 1.25mm & 2.5mm ferrules and MPO connectors, Blank Module to protect the mainframe’s rear connector, AC Charger, Shoulder Strap, USB Interface Cable, Versiv Open Source Software CD, Getting Started Guide, Soft Carrying Case.

The post FI-7000-MPO appeared first on tech4rents.

]]>
https://www.tech4rents.com/product/fi-7000-mpo/feed/ 0
OFP-100-QI https://www.tech4rents.com/product/ofp-100-qi/ Mon, 25 Sep 2017 10:22:38 +0000 http://tech4rents.com/?post_type=product&p=1498 Optifiber PRO Quad OTDR W/Inspection

The post OFP-100-QI appeared first on tech4rents.

]]>
OptiFiber® Pro OTDR

Built for the Enterprise

OptiFiber Pro is the first OTDR built from the ground up for enterprise fiber optic cabling testing. OptiFiber Pro is focused on reducing costs while enhancing productivity and improving network reliability.

  1. First OTDR with a smartphone user-interface
  2. Industry’s shortest event and attenuation dead zones
  3. Accelerate fiber certification with the fastest set-up and trace times
  4. SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  5. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  6. Instantaneous bi-directional averaging results included at no charge
  7. Improve resource utilization with custom configurations for projects and users
  8. Simplify use with “DataCenter OTDR™” mode and EventMap™ view
  9. Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

Features

Smartphone User Interface

  • Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.

Advantages:

  1. Single-touch tap and swipe control for selecting and scrolling menu items
  2. Multi-touch pinch to zoom for easy magnification control on a graphical fiber trace
  3. Task-focused design to reduce back and forth navigation through screens
  4. Capacitive touchscreen eliminates the need to recalibrate unlike legacy touchscreens
  5. Context sensitive on-screen help that gives users additional details or problem resolution suggestions

Optimized for the Datacenter

  • Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.With a simple one-touch selection, users enter DataCenter OTDR mode – without setup time for fine-tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters – end-detection algorithms, pulse widths, etc – without getting confused by the short links or number of connectors.

Advantages:

  1. Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links
  2. DataCenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber
  3. The EventMap feature depicts fiber events in a way that requires no trace analysis expertise

SmartLoop OTDR

  • SmartLoop OTDR enables automated testing and analysis of two fibers in a single test while meeting standard’s requirements. This patent pending process automatically separates the two fibers for individual pass/fail analysis, display, and reporting. Not only does this cut the testing time by at least half, it also enables instant bi-directional averaged test results without moving the OTDR to the far end. In addition to getting the job done quicker, SmartLoop OTDR further enhances the ease and speed of testing in environments where the far end is difficult of even dangerous to reach because the OTDR never has to be moved to the far end. In addition to getting the job done quicker, SmartLoop meets the standard’s requirements of leaving the launch and tail fibers in their initial locations during both bi-directional tests.
  • Test it right and test it fast with SmartLoop – included for free in all OptiFiber Pro modules.

 

Unique Certification with Flexibility and Efficiency

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With built-in project management, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

OptiFiber Pro enhances job efficiency by allowing the workflow planner to create and manage operator and job profiles per project – defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

Advantages:

  1. Full OTDR capability that certifies fiber performance based on job assignment for each operator
  2. Powerful project management facilitates OTDR sharing with clear job assignment for each operator
  3. Easy monitoring of job progress with pass/fail results
  4. On-screen report generation and upload to LinkWare™ application

 

Fiber Endface Inspection and Certification

OptiFiber Pro incorporates the FiberInspector Pro video inspection system which enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It’s 1-second automated PASS/FAIL certification, per IEC 61300-3-35, eliminates human subjectivity and enables anyone to become a fiber inspection expert. Results can be saved in the certification report alongside OptiFiber Pro’s OTDR results.

 

Other Key Features

Extremely short event and attenuation dead zoneThe OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area environments.

 

LinkWare™ management software

Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Two second trace per wavelength Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap, Table or Trace. The end result is less time spent testing and more time performing other tasks.

On-screen help – corrective action On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

LinkWare™ Live Test Results Management Service

Specifications

Key OTDR specifications

Multimode module Singlemode module Quad module
Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event dead zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation dead zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max distance range setting 40 km 130 km MM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test time (per wavelength) Auto setting: 5 sec (typical) Auto setting: 10 sec (typical) Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM – 2 sec (typical), MM – 180 sec (max)
SM – 10 sec (typical), SM – 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM – 3, 5, 10, 20, 40, 60, 90, 120, 180 sec

 

  1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
  4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
  5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
  6. SNR=1 method, 3 minute averaging, widest pulse width.
  7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
  10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  11. Does not include index of refraction error and does not include automatic event location error.
  12. dB variation per 1 dB step.
  13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.

 

Additional key specifications

FiberInspector probe specification
Magnification ~ 200X with OptiFiber Pro Display
Light source Blue LED
Power source Versiv mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (-20°C to +70°C)
Certifications CE (when used with the mainframe)

 

VFL specifications
On/Off control Mechanical switch and a button on the touch screen
Output power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS) ±3 nm
Output modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5 mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2

 

General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time
Tester Off Four hours to charge from 10% to 90% capacity
Tester On Six hours to charge from 10% to 90% capacity with the tester on

 

Environmental specifications
Operating temperature* -10ºC to 45ºC
Storage Temperature -10ºC to +60ºC
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with ac adapter
Storage altitude 12,000 m
EMC EN 61326-1

* Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.

 

Kit Components:

OptiFiber Pro Quad OTDR with inspection kit. This kit includes (1) Versiv Mainframe, (1) OptiFiber Pro Quad OTDR module, Shoulder Strap, Carry Case, USB Interface Cable, Versiv Open Source Software CD, AC Charger, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) SC/LC Multimode Launch Cables—50 µm, (2) SC/LC Singlemode Launch Cables—9 µm, (2) OTDR source port interchangeable LC adapters, USB Fiber Inspection Video Probe with 4 Tips, SC/SC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Statement of Calibration and Getting Started Guides

The post OFP-100-QI appeared first on tech4rents.

]]>
OFP-100-SI https://www.tech4rents.com/product/ofp-100-si/ Mon, 25 Sep 2017 10:20:18 +0000 http://tech4rents.com/?post_type=product&p=1496 Optifiber PRO Singlemode OTDR W/Inspection

The post OFP-100-SI appeared first on tech4rents.

]]>
OptiFiber® Pro OTDR

Built for the Enterprise

Looking for renting the OptiFiber PRO SingleMode OTDR with Inspection in Dubai, UAE or GCC?

OptiFiber Pro is the first OTDR built from the ground up for enterprise fiber optic cabling testing. OptiFiber Pro is focused on reducing costs while enhancing productivity and improving network reliability.

  1. First OTDR with a smartphone user-interface
  2. Industry’s shortest event and attenuation dead zones
  3. Accelerate fiber certification with the fastest set-up and trace times
  4. SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  5. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  6. Instantaneous bi-directional averaging results included at no charge
  7. Improve resource utilization with custom configurations for projects and users
  8. Simplify use with “DataCenter OTDR™” mode and EventMap™ view
  9. Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

Features

Smartphone User Interface

  • Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.Advantages:
    1. Single-touch tap and swipe control for selecting and scrolling menu items
    2. Multi-touch pinch to zoom for easy magnification control on a graphical fiber trace
    3. Task-focused design to reduce back and forth navigation through screens
    4. Capacitive touchscreen eliminates the need to recalibrate unlike legacy touchscreens
    5. Context sensitive on-screen help that gives users additional details or problem resolution suggestions

Optimized for the Datacenter

  • Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.With a simple one-touch selection, users enter DataCenter OTDR mode – without setup time for fine-tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters – end-detection algorithms, pulse widths, etc – without getting confused by the short links or number of connectors.Advantages:
    1. Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links
    2. DataCenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber
    3. The EventMap feature depicts fiber events in a way that requires no trace analysis expertise

SmartLoop OTDR

  • SmartLoop OTDR enables automated testing and analysis of two fibers in a single test while meeting standard’s requirements. This patent pending process automatically separates the two fibers for individual pass/fail analysis, display, and reporting. Not only does this cut the testing time by at least half, it also enables instant bi-directional averaged test results without moving the OTDR to the far end. In addition to getting the job done quicker, SmartLoop OTDR further enhances the ease and speed of testing in environments where the far end is difficult of even dangerous to reach because the OTDR never has to be moved to the far end. In addition to getting the job done quicker, SmartLoop meets the standard’s requirements of leaving the launch and tail fibers in their initial locations during both bi-directional tests.
  • Test it right and test it fast with SmartLoop – included for free in all OptiFiber Pro modules.


Unique Certification with Flexibility and Efficiency

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With built-in project management, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

OptiFiber Pro enhances job efficiency by allowing the workflow planner to create and manage operator and job profiles per project – defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

Advantages:

  1. Full OTDR capability that certifies fiber performance based on job assignment for each operator
  2. Powerful project management facilitates OTDR sharing with clear job assignment for each operator
  3. Easy monitoring of job progress with pass/fail results
  4. On-screen report generation and upload to LinkWare™ application

 

Fiber Endface Inspection and Certification

OptiFiber Pro incorporates the FiberInspector Pro video inspection system which enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It’s 1-second automated PASS/FAIL certification, per IEC 61300-3-35, eliminates human subjectivity and enables anyone to become a fiber inspection expert. Results can be saved in the certification report alongside OptiFiber Pro’s OTDR results.

 

Other Key Features

Extremely short event and attenuation dead zoneThe OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area environments.

LinkWare™ management software

Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Two second trace per wavelength Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap, Table or Trace. The end result is less time spent testing and more time performing other tasks.

On-screen help – corrective action On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

LinkWare™ Live Test Results Management Service

Specifications

Key OTDR specifications

Multimode module Singlemode module Quad module
Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event dead zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation dead zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max distance range setting 40 km 130 km MM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test time (per wavelength) Auto setting: 5 sec (typical) Auto setting: 10 sec (typical) Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM – 2 sec (typical), MM – 180 sec (max)
SM – 10 sec (typical), SM – 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM – 3, 5, 10, 20, 40, 60, 90, 120, 180 sec

 

  1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
  4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
  5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
  6. SNR=1 method, 3 minute averaging, widest pulse width.
  7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
  10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  11. Does not include index of refraction error and does not include automatic event location error.
  12. dB variation per 1 dB step.
  13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.

 

Additional key specifications

FiberInspector probe specification
Magnification ~ 200X with OptiFiber Pro Display
Light source Blue LED
Power source Versiv mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (-20°C to +70°C)
Certifications CE (when used with the mainframe)

 

VFL specifications
On/Off control Mechanical switch and a button on the touch screen
Output power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS) ±3 nm
Output modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5 mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2

 

General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time
Tester Off Four hours to charge from 10% to 90% capacity
Tester On Six hours to charge from 10% to 90% capacity with the tester on

 

Environmental specifications
Operating temperature* -10ºC to 45ºC
Storage Temperature -10ºC to +60ºC
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with ac adapter
Storage altitude 12,000 m
EMC EN 61326-1

* Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.

Kit Components:

OptiFiber Pro Singlemode OTDR kit with inspection kit. This kit includes (1) Versiv Mainframe, (1) OptiFiber Pro Singlemode OTDR module, Shoulder Strap, USB Interface Cable, Versiv Open Source Software CD, AC Charger, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) SC/LC Singlemode Launch Cables—9 µm, (1) OTDR source port interchangeable LC adapters, USB Fiber Inspection Video Probe with 4 Tips, SC/SC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Statement of Calibration and Getting Started Guides.

The post OFP-100-SI appeared first on tech4rents.

]]>
OFP-CFP-QI https://www.tech4rents.com/product/ofp-cfp-qi/ Mon, 25 Sep 2017 10:16:04 +0000 http://tech4rents.com/?post_type=product&p=1494 Optifiber PRO & Certifiber PRO Quad Insp

The post OFP-CFP-QI appeared first on tech4rents.

]]>
OptiFiber® Pro OTDR

Built for the Enterprise

OptiFiber Pro is the first OTDR built from the ground up for enterprise fiber optic cabling testing. OptiFiber Pro is focused on reducing costs while enhancing productivity and improving network reliability.

  1. First OTDR with a smartphone user-interface
  2. Industry’s shortest event and attenuation dead zones
  3. Accelerate fiber certification with the fastest set-up and trace times
  4. SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  5. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  6. Instantaneous bi-directional averaging results included at no charge
  7. Improve resource utilization with custom configurations for projects and users
  8. Simplify use with “DataCenter OTDR™” mode and EventMap™ view
  9. Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

Features

  • Smartphone User Interface
  • Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.Advantages:
    1. Single-touch tap and swipe control for selecting and scrolling menu items
    2. Multi-touch pinch to zoom for easy magnification control on a graphical fiber trace
    3. Task-focused design to reduce back and forth navigation through screens
    4. Capacitive touchscreen eliminates the need to recalibrate unlike legacy touchscreens
    5. Context sensitive on-screen help that gives users additional details or problem resolution suggestions

  • Optimized for the Datacenter
  • Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.With a simple one-touch selection, users enter DataCenter OTDR mode – without setup time for fine-tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters – end-detection algorithms, pulse widths, etc – without getting confused by the short links or number of connectors.Advantages:
    1. Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links
    2. DataCenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber
    3. The EventMap feature depicts fiber events in a way that requires no trace analysis expertise

  • SmartLoop OTDR
  • SmartLoop OTDR enables automated testing and analysis of two fibers in a single test while meeting standard’s requirements. This patent pending process automatically separates the two fibers for individual pass/fail analysis, display, and reporting. Not only does this cut the testing time by at least half, it also enables instant bi-directional averaged test results without moving the OTDR to the far end. In addition to getting the job done quicker, SmartLoop OTDR further enhances the ease and speed of testing in environments where the far end is difficult of even dangerous to reach because the OTDR never has to be moved to the far end. In addition to getting the job done quicker, SmartLoop meets the standard’s requirements of leaving the launch and tail fibers in their initial locations during both bi-directional tests.
  • Test it right and test it fast with SmartLoop – included for free in all OptiFiber Pro modules.



  • Unique Certification with Flexibility and Efficiency

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With built-in project management, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

OptiFiber Pro enhances job efficiency by allowing the workflow planner to create and manage operator and job profiles per project – defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

Advantages:

  1. Full OTDR capability that certifies fiber performance based on job assignment for each operator
  2. Powerful project management facilitates OTDR sharing with clear job assignment for each operator
  3. Easy monitoring of job progress with pass/fail results
  4. On-screen report generation and upload to LinkWare™ application

 

  • Fiber Endface Inspection and Certification

OptiFiber Pro incorporates the FiberInspector Pro video inspection system which enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It’s 1-second automated PASS/FAIL certification, per IEC 61300-3-35, eliminates human subjectivity and enables anyone to become a fiber inspection expert. Results can be saved in the certification report alongside OptiFiber Pro’s OTDR results.

 

  • Other Key Features

Extremely short event and attenuation dead zone
The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area environments.

LinkWare™ management software
Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Two second trace per wavelength 
Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap, Table or Trace. The end result is less time spent testing and more time performing other tasks.

On-screen help – corrective action 
On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

  • LinkWare™ Live Test Results Management Service

 

Specifications

Key OTDR specifications

Multimode module Singlemode module Quad module
Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event dead zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation dead zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max distance range setting 40 km 130 km MM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test time (per wavelength) Auto setting: 5 sec (typical) Auto setting: 10 sec (typical) Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM – 2 sec (typical), MM – 180 sec (max)
SM – 10 sec (typical), SM – 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM – 3, 5, 10, 20, 40, 60, 90, 120, 180 sec

 

  1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
  4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
  5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
  6. SNR=1 method, 3 minute averaging, widest pulse width.
  7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
  10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  11. Does not include index of refraction error and does not include automatic event location error.
  12. dB variation per 1 dB step.
  13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.

 

Additional key specifications

FiberInspector probe specification
Magnification ~ 200X with OptiFiber Pro Display
Light source Blue LED
Power source Versiv mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (-20°C to +70°C)
Certifications CE (when used with the mainframe)

 

VFL specifications
On/Off control Mechanical switch and a button on the touch screen
Output power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS) ±3 nm
Output modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5 mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2

 

General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time
Tester Off Four hours to charge from 10% to 90% capacity
Tester On Six hours to charge from 10% to 90% capacity with the tester on

 

Environmental specifications
Operating temperature* -10ºC to 45ºC
Storage Temperature -10ºC to +60ºC
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with ac adapter
Storage altitude 12,000 m
EMC EN 61326-1

* Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.

Kit Components:

OptiFiber Pro Quad OTDR and CertiFiber Pro Quad kit with inspection kit. This kit includes (1) Versiv Mainframe & Remote, (1) OptiFiber Pro Quad OTDR module, (2) CertiFiber Pro Quad OLTS modules, (2) HandStraps, (2) Shoulder Straps, (2) Carry Cases, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, (2) Quick Clean Cleaners (1.25/2.50 mm), (2) SC/LC Multimode Launch Cables—50 µm, (2) SC/LC Singlemode Launch Cables—9 µm, (2) OTDR source port interchangeable LC adapters, USB Fiber Inspection Video Probe with 4 Tips, SC/SC Simplex Adaptor, (2) LC/LC Simplex Adaptor, SC/LC EF-compliant MM TRC Kit 50 µm, TRC Carry Case, (2) Launch Fiber Hanging straps and magnets, Statement of Calibration and Getting Started Guides.

The post OFP-CFP-QI appeared first on tech4rents.

]]>
OFP-Q-ADD https://www.tech4rents.com/product/ofp-q-add/ Mon, 25 Sep 2017 10:13:41 +0000 http://tech4rents.com/?post_type=product&p=1492 Optifiber Pro Quad Add On Kit

The post OFP-Q-ADD appeared first on tech4rents.

]]>
OptiFiber® Pro OTDR

Built for the Enterprise

OptiFiber Pro is the first OTDR built from the ground up for enterprise fiber optic cabling testing. OptiFiber Pro is focused on reducing costs while enhancing productivity and improving network reliability.

  1. First OTDR with a smartphone user-interface
  2. Industry’s shortest event and attenuation dead zones
  3. Accelerate fiber certification with the fastest set-up and trace times
  4. SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  5. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  6. Instantaneous bi-directional averaging results included at no charge
  7. Improve resource utilization with custom configurations for projects and users
  8. Simplify use with “DataCenter OTDR™” mode and EventMap™ view
  9. Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

Features

  • Smartphone User Interface
  • Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.Advantages:
    • Single-touch tap and swipe control for selecting and scrolling menu items
    • Multi-touch pinch to zoom for easy magnification control on a graphical fiber trace
    • Task-focused design to reduce back and forth navigation through screens
    • Capacitive touchscreen eliminates the need to recalibrate unlike legacy touchscreens
    • Context sensitive on-screen help that gives users additional details or problem resolution suggestions

  • Optimized for the Datacenter
  • Driven by server virtualization and multi-gigabit links between servers, networks and storage, the datacenter architecture employs more patch cords and dense topology connectors, rendering carrier-class OTDRs with long dead zones ineffective. OptiFiber Pro not only makes fiber deployment in datacenters possible, but provides the highest level of accuracy for quick problem resolution.With a simple one-touch selection, users enter DataCenter OTDR mode – without setup time for fine-tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters – end-detection algorithms, pulse widths, etc – without getting confused by the short links or number of connectors.Advantages:
    • Ultra-short event and attenuation dead-zones precisely locates events and faults on fiber links
    • DataCenter OTDR™ mode automatically sets the configuration to quickly test datacenter fiber
    • The EventMap feature depicts fiber events in a way that requires no trace analysis expertise

  • SmartLoop OTDR
  • SmartLoop OTDR enables automated testing and analysis of two fibers in a single test while meeting standard’s requirements. This patent pending process automatically separates the two fibers for individual pass/fail analysis, display, and reporting. Not only does this cut the testing time by at least half, it also enables instant bi-directional averaged test results without moving the OTDR to the far end. In addition to getting the job done quicker, SmartLoop OTDR further enhances the ease and speed of testing in environments where the far end is difficult of even dangerous to reach because the OTDR never has to be moved to the far end. In addition to getting the job done quicker, SmartLoop meets the standard’s requirements of leaving the launch and tail fibers in their initial locations during both bi-directional tests.
  • Test it right and test it fast with SmartLoop – included for free in all OptiFiber Pro modules.

 

  • Unique Certification with Flexibility and Efficiency

An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With built-in project management, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

OptiFiber Pro enhances job efficiency by allowing the workflow planner to create and manage operator and job profiles per project – defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

Advantages:

  • Full OTDR capability that certifies fiber performance based on job assignment for each operator
  • Powerful project management facilitates OTDR sharing with clear job assignment for each operator
  • Easy monitoring of job progress with pass/fail results
  • On-screen report generation and upload to LinkWare™ application

 

  • Fiber Endface Inspection and Certification

OptiFiber Pro incorporates the FiberInspector Pro video inspection system which enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It’s 1-second automated PASS/FAIL certification, per IEC 61300-3-35, eliminates human subjectivity and enables anyone to become a fiber inspection expert. Results can be saved in the certification report alongside OptiFiber Pro’s OTDR results.

 

  • Other Key Features

Extremely short event and attenuation dead zone
The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area environments.

LinkWare™ management software
Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Two second trace per wavelength 
Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap, Table or Trace. The end result is less time spent testing and more time performing other tasks.

On-screen help – corrective action 
On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-to-read, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

 

  • LinkWare™ Live Test Results Management Service

Specifications

Key OTDR specifications

Multimode module Singlemode module Quad module
Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types 50/125 µm
62.5/125 µm
Singlemode 50/125 µm
62.5/125 µm
Singlemode
Event dead zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation dead zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max distance range setting 40 km 130 km MM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm 3 cm to 400 cm 3 cm to 400 cm
Pulse widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test time (per wavelength) Auto setting: 5 sec (typical) Auto setting: 10 sec (typical) Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM – 2 sec (typical), MM – 180 sec (max)
SM – 10 sec (typical), SM – 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM – 3, 5, 10, 20, 40, 60, 90, 120, 180 sec

 

  1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  2. Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < – 50 dB for singlemode.
  3. For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
  4. Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
  5. Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
  6. SNR=1 method, 3 minute averaging, widest pulse width.
  7. 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  8. 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  9. 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
  10. 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
  11. Does not include index of refraction error and does not include automatic event location error.
  12. dB variation per 1 dB step.
  13. Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.

 

Additional key specifications

FiberInspector probe specification
Magnification ~ 200X with OptiFiber Pro Display
Light source Blue LED
Power source Versiv mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (-20°C to +70°C)
Certifications CE (when used with the mainframe)

 

VFL specifications
On/Off control Mechanical switch and a button on the touch screen
Output power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS) ±3 nm
Output modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5 mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2

 

General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time
Tester Off Four hours to charge from 10% to 90% capacity
Tester On Six hours to charge from 10% to 90% capacity with the tester on

 

Environmental specifications
Operating temperature* -10ºC to 45ºC
Storage Temperature -10ºC to +60ºC
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with ac adapter
Storage altitude 12,000 m
EMC EN 61326-1

* Using battery power. With AC power: 0ºC to 45ºC. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35ºC for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.

OptiFiber Pro Add on Kit – includes OptiFiber Pro Quad OTDR Module, (2) SC/LC Multimode Launch Cables—50 µm, (2) SC/LC Singlemode Launch Cable—9 µm, (2) OTDR source port interchangeable LC adapters, SC/SC Simplex Adaptor, LC/LC Simplex Adaptor, (2) Launch Fiber Hanging straps and magnets, Carry Case, Statement of Calibration and Getting Started Guide.

The post OFP-Q-ADD appeared first on tech4rents.

]]>
FI-7000 https://www.tech4rents.com/product/fi-7000/ Fri, 22 Sep 2017 14:23:56 +0000 http://tech4rents.com/?post_type=product&p=1486 FI-7000 FiberInspector™ Pro

The post FI-7000 appeared first on tech4rents.

]]>
Fiber optic connector end-face contamination is a leading cause of fiber failures. Dirt and contaminant cause insertion loss and back-reflection that inhibits optical transmission and causes havoc with transceivers. Fiber loss and OTDR testing can expose this problem, but in many cases, dirty connections make fiber testing time consuming and inaccurate.

Since dirt can be an issue before, during, or after fiber optic certification testing, and migrate from one fiber optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected. Further, mating contaminated fiber optic connectors can cause permanent damage as microscopic debris is crushed between end-faces in physical contact. Even factory terminated patch cords or pigtails must be inspected as protective caps do not keep fiber optic connector end-faces clean. Avoiding this common cause of failure, starts with inspecting the fiber optic connector end-face and eliminating any contamination before insertion into a bulkhead or piece of equipment.

The FI-7000 FiberInspector Pro is a fiber optic inspection scope that allows you to inspect and certify fiber optic connector end-faces in 1 seconds so you can get the job done the first time. This fiber optic inspection scope provides automated PASS/FAIL certification take the guess work out of fiber inspection so anyone can be a fiber expert.

1-second automated PASS/FAIL certification of fiber optic connector end-faces
  1. Automated Pass/Fail certification of fiber optic connector end-faces
  2. Graphical indication of problem areas due to contamination, pits, chips, and scratches
  3. Certify to industry standards – IEC 61300-3-35
  4. Eliminate human subjectivity from fiber optic connector end-face measurements
  5. Save fiber optic connector end-face views during certification process
  6. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection

Features

  • Fiber Inspection Certification
    • Certify your fiber end-faces to industry standards – IEC 61300-3-35. Or if you prefer, you can manually grade your end-faces.
  • Graphical indication of Problem Areas
    • FiberInspector Pro highlights defects found on fiber end-faces. Instead of just coloring the defect area, the FI-7000 colors the defect and highlights the defect’s background so that the defect is clearly visible. Defects that fail the standard’s requirements are colored Red, while defects that pass are colored Green.
  • Store End-face Images
    • Store both end-face images of a fiber directly in your Versiv test results. Combine end-face images with CertiFiber Pro OLTS and/or OptiFiber Pro OTDR test results for the complete history of your fiber cabling health.
  • Built on the Versiv Platform
    • The FI-7000 is built on the Versiv Cable Certification Platform which enables you to easily add optical loss (OLTS) and Optical Time Domain Reflectometry (OTDR) or even twisted pair copper or network analysis functionality to FI-7000. Product add-on kits are available for the DTX CableAnalyzer, CertiFiber Pro OLTS, and OptiFiber Pro OTDR.
  • Versiv’s ProjX™ System
    • Versiv’s ProjX™ System manages jobs from setup to systems acceptance, ensuring that all tests are completed correctly. Enter the testing details for a job once, and ProjX stores them in a project file with a name the whole team can understand. Change modules or jobs without having to re-enter details. Support multiple testers on the same job by sharing project files via USB sticks or email. Easy just met efficient.
      Set-up or view test limits, and testing attributes. Project menu screen shows percent complete per job. Project Specific screen shows up to the minute project details.
  • Taptive™ User Interface
    • Now you can test across multiple media types and requirements as easy as using a smartphone. Simply, select the job you’re working on, and the large display confirms the test that needs to be performed. Taptive helps you tap into the overall cabling infrastructure faster and more easily.User Interface for Speeds Troubleshooting
    • Taptive user interface simplifies set-up,eliminates errors and speeds troubleshooting
  • LinkWare™ Live Test Results Management Service
    1. LinkWare Live is a cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device.  With LinkWare Live, you can
    2. Keep track of every test on every job.  Get an overview of every project from any smart device. Drill down to each individual test. Instantly receive notification of incorrect test setting or cable IDs.
    3. Get it right the first time. Define cable IDs and test settings from your PC or tablet. Then send them to the testers or Brother printers at the jobsite for mistake-free testing and labeling.
    4. Keep your testers up to date. Standards can change without notice, and an out-of-date test report can mean hours of re-testing. LinkWare Live automatically ensures your testers are running the latest.
    5. Stop wasting time and gas driving testers back to the office. Upload your test results straight from the job site to LinkWare Live over Wi-Fi. Then download them automatically to the right job for fast report generation with LinkWare PC.
    6. Avoid Project Delays. Track the last used location and monitor the status of all testers to ensure they are always calibrated and running the latest firmware*
    7. Supports all Versiv models: DSX CableAnalyzer Series, CertiFiber Pro, OptiFiber Pro, and the FI-7000.
  • LinkWare™ Management Software
    1. Project managers have full capabilities to monitor workflow and consolidate test results.
    2. LinkWare pulls data togther into a single report that is easy for customers to understand, showcasing quality and workmanship. LinkWare stats, provides automated statistical reports that turns test results into charts to reveal performance. The report even summarizes your entire cabling and fiber infrastructure in one compact, graphical format, so it is easy to verify margins and anomalies.
  • PASS/FAIL Fiber End-face Grading
    • The FI-7000’s PASS/FAIL fiber end-face grading is available to all Versiv owners. It is included in Versiv firmware v3.0 and higher. To enjoy this free fiber end-face grading, just download the latest Versiv firmware and create a new Project using FiberInspector as the test.

Specifications

Technical Specifications

Inspection Probe specifications
2M pixels Blue LED
Light source Blue LED
Power source Versiv mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size 0.5 µm
Dimensions Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight 200 g
Temperature range Operating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (-20°C to +70°C)
Certifications CE
General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life Eleven hour with Inspection probe attached
Charge Time
Tester Off Four hours to charge from 10% to 90% capacity
Tester On Six hours to charge from 10% to 90% capacity with the tester on
Environmental specifications
Operating temperature* -18ºC to 45ºC
Non-operating temperature -30ºC to 60ºC
Operating altitude 4,000 m (13123 ft)
3200 m (10,500 ft) with ac adapter
Storage altitude 12,000 m
EMC EN 61326-1
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.

The FI-7000 FiberInspector Pro contains:

Versiv Mainframe, USB Fiber Inspection Video Probe with 4 tips in a box (LC, FC/SC bulkhead, 1.25 and 2.5mm universal), Blank Module to protect the mainframe’s rear connector, AC Charger, Shoulder Strap, USB Interface Cable, Versiv Open Source Software CD, Getting Started Guide, Soft Carrying Case.

The post FI-7000 appeared first on tech4rents.

]]>
DSX-8000QOI https://www.tech4rents.com/product/dsx-8000qoi/ Mon, 25 Sep 2017 08:53:31 +0000 http://tech4rents.com/?post_type=product&p=1488 2GHZ QUAD OTDR OLTS Inspc

The post DSX-8000QOI appeared first on tech4rents.

]]>
DSX CableAnalyzer™ Series

Accelerates every step of the copper certification process

  1. Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  2. Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  3. ProjX™ system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
  4. Taptive™ user interface simplifies set-up, and eliminates errors
  5. Analyze test results and create professional test reports using LinkWare™ management software
  6. Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting
  7. Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  8. Endorsed by cabling vendors worldwide
  9. Built in Alien Crosstalk testing capability
  10. Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

The DSX CableAnalyzer Series copper test solution enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Comparing the DSX-8000 and DSX-5000

The DSX CableAnalyzer Series family is based on two modules: the DSX-5000 and DSX-8000. The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.

Copper Certification
DSX-8000 CableAnalyzer™ DSX-5000 CableAnalyzer™
Category 6A / Class EA test time 8 seconds 10 seconds
Category 8 / Class I/II test time 15 seconds
HDTDX/HDTDR diagnostic test times ≈ 3 seconds ≈ 3 seconds
Internal memory ≈ 5,000 Cat 8 with plots
≈ 12,000 Cat 6A with plots
≈ 12,000 Cat 6A with plots
Level V Accuracy (1 GHz)
Level VI/2G Accuracy (2 GHz)
Resistance Unbalance measurement
Shield integrity check
TCL measurement
ELTCTL measurement
CDNEXT measurement
CMRL measurement
Built in Alien XTalk module
Channel Adapter 2 GHz Range 1 GHz Range
Permanent Link Adapter 2 GHz Range 1 GHz Range
Optional Accessories
Patch cord adapters Category 5e, 6 and 6A patch cord Category 5e, 6 and 6A patch cord
Coax Adapter
M12 Adapter
TERA Adapter Coming Summer 2017
GG45 Adapter Coming Summer 2017

Unique Features:

  1. Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  2. LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  3. ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  4. Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  5. LinkWare PC management software provides unmatched analysis of test results and professional test reports
  6. The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Standards:

  1. Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
  2. Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) –IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
  3. TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
  4. Screen continuity along path of cabling

Performance:

  1. Eight second Cat 6A test time contributes to the fastest way to gain certification
  2. Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  3. Manage up to 12,000 Cat 6A test results with full graphics
  4. Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  5. Over 1 billion links reported on LinkWare PC management software

ProjX™ Management System Manages Complex Jobs with Ease

Manage up to 12,000 Cat 6A test results with full graphics

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX CableAnalyzer Series provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The “Fix Later” selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.

Project Setup screen
Project menu screen shows
percent complete per job.
Arrow
Project Menu Screen Specific screen shows up to the minute project details.
Arrow
Project Test Setup Screen
Set-up or view test limits, and
testing attributes.

Performs with Unsurpassed Speed

Eight second Cat 6A test time and the fastest way to submit your certification results

No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 8 seconds or certify two fibers at two wavelengths in just 3 seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

Passing Test Results

LinkWare™ Live Test Results Management Service
LinkWare™ PC Cable Test Management Software
Versiv Platform is Ready for Today’s and Tomorrow’s Jobs

Troubleshoot Like an Expert – Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting

The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are located on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer Series removes this limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.

HTDTX shows the far end connection is clearly the issue Feature Simple Diagnostics
High Definition Time Domain Crosstalk (HTDTX) shows the far end connection in clearly the issue Features simple diagnostics based decades of Fluke Networks troubleshooting experience

Shield continuity historically is a direct current (DC) measurement with no distance to fault available. Other testers run a simple resistance test to verify that the shield has continuity. These tests have been shown to be inaccurate, sometime confusing a ground path as shield continuity and not correctly identifying a break in the shield. Other testers may tell you there is a break in a shield, but not pinpoint the exact location giving no indication of where to start rework. The DSX CableAnalyzer Series is the first field tester to report distance to any shield integrity issues, reporting the true status of the screen continuity. This is especially important in\ datacenters and Cat 8 installations where screen continuity is critical to maintaining alien crosstalk performance of screened cabling.

Wiremap Shows Distance to fault, break and short

Specifications

 

Cable Types
Shielded and unshielded pair LAN cabling TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω
ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω

 

Standard Link Interface Adapters
Permanent link adapters Plug type: shielded RJ45
Optional Plug type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)

 

Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2
ISO/IEC Class C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequency DSX-8000: 2000 MHz;
DSX-5000: 1000 MHz

 

General Specifications
Speed of Autotest DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA8 seconds. Full 2-way Autotest of Category 8: 16 seconds
DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with shock absorbing overmold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote: Lithium ion battery pack, 7.2 V
Typical battery life: 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year

 

Environmental Specifications
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -14°F to +140°F (-10°C to +60°C)
Operating relative humidity 0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude 13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMC EN 61326-1

 

Performance Specifications **
DSX-8000 Category 8 test modes (or lower link categories) ANSI/TIA-1152 Level 2G
Class I/II test modes Proposed standard IEC 61935-1 Ed. 5 Level VI
DSX-5000 Category 6A/Class EA test modes (or lower link categories) Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes Exceed Level V requirements as in the draft 4th edition of IEC 61935-1.

 

Length of Twisted Pair Cabling1
Without Remote With Remote
Range 800 m (2600 ft) 150 m (490 ft)
Resolution 0.1 m or 1 ft 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)

 

Propagation Delay
Without Remote With Remote
Range 4000 ns 750 ns
Resolution 1 ns 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)

 

Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns

 

DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.

Kit Components:

1 Versiv Mainframe & Remote, (2) DSX-8000 CableAnalyzer modules, (2) CertiFiber Quad OLTS modules, OptiFiber Quad OTDR module, Set of Cat 8/Class I Permanent Link Adapters, Set of Cat 8/Class 1 Channel Adapters, (2) Headsets, (2) HandStraps, (2) Shoulder Straps, Hard sided Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, (2) Universal Couplers, (2) AxTalk Terminators, (2) Quick Clean Cleaners (1.25/2.50 mm), SC/SC Simplex adapters, 2 SC/LC Multimode Launch Cables—50 µm, 2 SC/LC Singlemode Launch Cable—9 µm, USB Fiber Inspection Video Probe with 4 Tips, (2) LC/LC Simplex Adapter, SC/LC EF-Compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carry Case, Statement of Calibration and Getting Started Guides.

The post DSX-8000QOI appeared first on tech4rents.

]]>